ODrive Sensorless

Aus Hennings Wiki

https://rbts.co/Blog/Electronics/odrive-3.6-sensorless-setup/

"axis0.config.load_encoder": 4,
"axis0.config.commutation_encoder": 4,
# 8.27 / 330(KV)
"axis0.config.motor.torque_constant": 0.025060605257749557,
dev0.axis0.config.sensorless_ramp.current = 5
dev0.axis0.controller.config.vel_limit = 50
dev0.axis0.requested_state = AXIS_STATE_MOTOR_CALIBRATION

Stecker:

Stecker
Beschreibung RS Best.-Nr ODrive Pro Port
Buchsengehäuse 10-polig Mikro-Fit 3.0 2332781 ISOLATED IO J12
Buchsengehäuse 14pol M-Fit 3.0 2373596 FEEDBACKIO J8
Buchsengehäuse 4-polig Mikro-Fit 3.0 2332753P CAN IO
MICRO-FIT 150mm 20 AWG Pre-Crimped Lead 1260317
Steckverbinder GH Raster 1,25mm 5-polig 7521740 Debug IO J7
Steckverbinder GH Raster 1,25mm 12-polig 7521759 MISC IO J14
GH Double ended Wire + Contacts-300mm 8201403